Detail Biochemistry Analyzer > BIOBASE-DIAMOND, Email: K111444888@ Yahoo.com, K111222999@ Yahoo.com, Telp 081385152874, Magdalena, Telp 082123847472, Lambok

Technical parameter: n Model: BIOBASE-DIAMOND n Type: discrete, fully automated n Absorbance method: direct analysis through reaction cup, reaction cup is cuvette. n Analysis method: end point, two points, kinetic method, turbidimetry n Programming items: programmable for any test item n Analysis items: analyzing max 45items at the same time n Max speed: 400test/ hour with single reagent n Sample settings: 60sample positions, including standard, quality control and emergency; can be used primary tubes or serum cups n Sample volume: 3 ul-50 ul ( step by 0.1 ul) , high precision injector ( dilution vessel) is prepared n Temperature control: 1. temperature fluctuation of reaction tray is + 0.1 2. Reagent bank in refrigerator. n Reagent positions: 45 refrigerated reagent positions n Reagent volume: R1: 25-300 ul; R2: 10-150 ul( step by 1 ul) , support reagent from different countries n Liquid level induction: both reagent probe and sample probe have functions of double liquid level induction and track in accordance with quantities n Reaction time: 10minutes n Cuvette: 120 independent reaction cuvettes( optical path length 6mm) n Cleaning: automatically cleaning cuvettes and drying n Calibration: one-point, multipoint n Light source: halogen-tungsten lamp n Receiver: 8 imported photo receivers n Testing wavelength: single and double wavelength test n Wavelength range: 340, 405, 510, 546, 578, 600, 660, 700( three of them can be defined by the users) , adopting reversed optics n Linear range: 0.000-2.500Abs n System adjustment: analyzer can record the blank value and get more accurate result after deducting blank base value of each cuvette n Emergency function: placing emergency sample at random and quality control in any place of sample tray, automatic priority to test n Automatic stirring function: yes n Quality control: inserting quality control at random, the same item can be reached 6quality controls n Software: windows 2000 professional or windows XP. Have plenty of functions of inquiries, convenient to use. n Data processing: reaction curve detection and data display function in the whole process n Printout: user can modify the printing format by his own n Power supply: AC220V+ 22V 50Hz+ 1Hz n Dimension: 1020mm 830mm 1220mm Email: k111444888@ yahoo.com, k111222999@ yahoo.com, Telp 081385152874, Magdalena, Telp 082123847472, Lambok . .
Tampilkan Lebih Banyak