* Ranging from compact sized type to acid and organic
solvent handling type.
* Compac type for 1, 5 ml microtube suitable for
concentration and drying after ethanol precipitation,
Model CVE-1000.
* Application diaphgram vacuum pump built-in type
suitable for solvent removal, model CVE-2000.
* Application for low-temperature concentrating of
biochemical substance, Model CVE-200D.
* Application for TFA, DMF, and DMSO suitable for
concentrating synthetic sample of combinatorial
chemistry and removing the solvent, Model CVE-3100
A. Characteristic of CVE series
1. Model : CVE-1000
Corrotion resistance of chamber water : o
Corrotion resistance of chamber alkohol : o
Corrotion resistance of chamber acid : x
Corrotion resistance of chamber organic solvent : x
Rotor material ( surface material) : Aluminium ( ..)
Vacuum pump : Option
Lid Material : Acrylic
2. Model : CVE-2000
Corrotion resistance of chamber water : o
Corrotion resistance of chamber alkohol : o
Corrotion resistance of chamber acid : -
Corrotion resistance of chamber organic solvent : o
Rotor material ( surface material) : Aluminium
( alumite)
Vacuum pump : Option
Lid Material : PVC
3. Model : CVE-200D
Corrotion resistance of chamber water : o
Corrotion resistance of chamber alkohol : o
Corrotion resistance of chamber acid : -
Corrotion resistance of chamber organic solvent : -
Rotor material ( surface material) : Aluminium
( Anti corotion treatment)
Vacuum pump : Option
Lid Material : Acrylic
4. Model : CVE-3100
Corrotion resistance of chamber water : o
Corrotion resistance of chamber alkohol : o
Corrotion resistance of chamber acid : o
Corrotion resistance of chamber organic solvent : o
Rotor material ( surface material) : SUS ( teflon)
Vacuum pump : Option
Lid Material : Glass + PVC
B. Capacity and temperature range of CVE series
1. Model : CVE-1000
No. of tubes to be handled microtube : 12-
No. of tubes to be handled test tube ( max.dia.) : 12...
2. Model : CVE-2000
No. of tubes to be handled microtube : 24
No. of tubes to be handled test tube ( max.dia.) : 16
3. Model : CVE-200D
No. of tubes to be handled microtube : 96
No. of tubes to be handled test tube ( max.dia.) : 36
4. Model : CVE-200D
No. of tubes to be handled microtube : 96
No. of tubes to be handled test tube ( max.dia.) : 48
.